Skip to main content
CourtGPT logoCourtGPT
Directory
Law
For Attorneys
Blog
AppointmentsSign InSign Up
§ 5-25-700 — South Carolina Law | CourtGPT
  1. Home/
  2. Laws/
  3. South Carolina/
  4. Title 5 - Municipal Corporations/
  5. Chapter 25 - Building Codes and Fire Prevention/
  6. § 5-25-700
South Carolina Legal Code

§ 5-25-700

Ask AI about this
No stovepipe shall pass through any roof window or weatherboarding and no stovepipe in any building with wood or combustible floors, ceilings or partitions shall enter any flue unless such pipe shall be at least twelve inches from such floors, ceilings or partitions, or unless it is properly protected by a metal shield, in which case the distance shall not be less than six inches. When stovepipes pass through wooden partitions of any kind or other woodwork, they shall be guarded by either a double collar of metal, with at least three inches air space and holes for ventilation, or by a soapstone or burnt-clay ring not less than one inch in thickness extending through the partition or other woodwork. HISTORY: 1962 Code Section 47-1237; 1952 Code Section 47-1237; 1942 Code Section 7507; 1932 Code Section 7507; Civ. C. '22 Section 4622; 1917 (30) 77.